Alpha Omega Instruments Series 2000 Percent Oxygen Analyzer

$ 396

Availability: 100 in stock

Description

Alpha Omega Instruments Series 2000 Percent Oxygen Analyzer
Extended Life Oxygen Sensor with EES
Ensures trouble-free and cost-effective operation with a useful life of up to four years.
Acid Gas Resistant Sensor
Save thousands of dollars versus other manufacturer
Numerous Mechanical Configurations
NEMA 4 and NEMA 7 enclosures suitable for a wide variety of applications.
Single and Three Range Options
Measure tenths of percent to 100%
Visual and Audible Alarms Included along with two analog recorder outputs.
Ensures the highest level of protection and reliability.
PERFORMANCE
Measurement Ranges (Percent Oxygen) Single Range 0-100 0-25 Three Range 0-10/25/100 0-5/10/25 0-1/10/25
Accuracy¹: ±1% of full scale (± 5% on the 0-1% range)
¹Stated at constant temperature and constant pressure
Linearity: ±1%
Response Time: 90% of full scale response in less than 20 seconds (typical)
Sensor Type: Ambient Temperature Electrochemical Sensor with EES
Temperature Compensation: Standard
Pressure Compensation: Standard
Operating Temperature: 40° to 104° F (5° to 40°C) <40°F (<5°C) use heated sensor enclosure >104°F (>40°C) cooling of sensor required
Warranty: 2years electronics/1 years sensor
ELECTRICAL
Display: 0.4″ (10.2 mm) high, 4-1/2digit LCD
Resolution: 0.1 %
Input power is universal AC (90-264VAC), 50-60Hz – battery backup available as an option for some models
Outputs: 4-20 mADC and 0-2 VDC standard as is a TTL output for range identification. RS-232C or RS-485 serial communication optional.
Oxygen Alarm Relays: Three (3) SPDT Form C contacts rated 10A @ 30 VDC/115/230 VAC. User selectable for fail-safe or non fail-safe.
Instrument Status Alarm: Rated identically to the O2 relays
Audible Alarm: Internal buzzer with audible cancel
SAMPLE GAS CHARACTERISTICS
Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liter/min)
Sample Gas Temperature: 40° to 104° F (5° to 40°C)
Sample Gas Pressure Limits: 0.1 to 1.5 psig (0.007 to 0.1 kg/cm2).
Entrained Solids: <3 mg/ft³: no in-line filter required >3 mg/ft³: in-line filter is required
Hydrocarbon Mist: <0.7 mg/ft³: no in-line filter required >0.7 mg/ft³: in-line filter is required
CONSTRUCTION²
Electronics Control Unit: Polycarbonate with a hinged clear front cover
²other mechanical configurations available-consult factory
Gas Connections: Quick connect for 1/4” OD flex tubing or optional 1/4” stainless steel compression fittings
Sensor Mounting: Local or optional remote mounting
Dimensions: Length: 9.45 in (240.5 mm), Width: 6.50 in. (165.1 mm), Depth: 6.20 in. (157.5 mm)
Weight: 11lbs (4.98 kg) (Bench-top Configuration.)